Home › Electrical measurement › Energy meters › EMT132
EMT132 energy meter
EMT13x family · 1 DIN module

EMT132

Three-phase power analyser in 1 DIN module, low-voltage powered from the T-BUS connector.

  • Power and RS485 on the T-BUSSeveral meters side by side on the DIN rail, without wiring each module.
  • 4 kV insulationSELV 10–36 Vdc or 19–26 Vac supply, isolated from the measuring inputs.
  • Class 0.5 S in 1 moduleHarmonics up to the 63rd and logging in the FULL version.
Class 0.5 Sactive energy
6400samples/s at 50 Hz
1 moduleDIN · 93×69×17 mm
63°harmonic (FULL)
Technical specifications

Technical data

The boxes highlighted in green are specific to the EMT132; the others are common to the whole EMT13x family.

Power supplyEMT132 only

Type
SELV, from the T-BUS connector
Voltage
10–36 Vdc · 19–26 Vac
Consumption
< 1,5 W
T-BUS connector
Power and RS485 communication

InsulationEMT132 only

Power supply / measuring inputs
4 kV
RS485 / measuring inputs
4 kV
Power supply / RS485
1,5 kV

Measuring inputs

Rated voltage
85–265 Vac L-N · 150–450 Vac L-L
Operating frequency
DC / 1–65 Hz
.I input (current-output CT)
In 5 A (or 1 A) · Imax 6 A · starting current 5 mA · < 1 VA per phase · overload 40 A for 500 ms
.V input (333 mV / Rogowski)
Vn 333 mV · Vmax 500 mV · 220 kΩ · built-in integrator for Rogowski coils
Measurement type
TRMS · 6400 samples/s at 50 Hz, 7680 at 60 Hz

Accuracy (25 ± 5 °C, 50 Hz)

Active energy
Class 0.5 S (EN 62053-22) · class C (EN 50470-1/3)
Reactive energy
Class 0.5 S (EN 62053-24)
Voltage · current
± 0.2 % rdg · ± 0.3 % rdg
Power
± 0.3 % rdg (5–100 % In) · ± 0.4 % rdg (1–5 % In)
Frequency
± 0,008 Hz (45–65 Hz)
THD · harmonics
± 0.3 % · magnitude ± 3 % up to the 16th, ± 5 % up to the 63rd

Communication and outputs

RS485
Modbus RTU · 1200–115,200 baud · up to 247 addresses · on terminal or T-BUS connector
Wi-Fi
2.4 GHz 802.11 b/g/n · Modbus TCP, HTTP, MQTT, SNTP · up to 10 clients · station and access point
NFC
Reading the configuration parameters
Digital output
1 solid-state (MOSFET) · < 40 V, < 100 mA · alarm or pulses/kWh
Logging
Internal flash memory up to 1 MB (FULL)
Configuration
Built-in web server, app, JSON API · from cloud (FULL)

General

Display
160×80 pixel colour, with touch button
Dimensions
93×69×17 mm · 1 DIN module · grey PBT
Protection rating
IP20 · pollution degree 2
Temperature
Operating −25 to +65 °C · storage −40 to +85 °C
Humidity · altitude
10–90 % non-condensing · up to 2000 m
Measurement category
CAT III 300 V
Standards
EN 61010-1, EN 61010-2-030 · EN 61000-4-2/3/4/5/6 · EN 55032 class B
Versions

BASE o FULL

Same hardware, same basic measurements. The FULL version adds power quality, logging, oscilloscope and cloud connection.

FunctionBASEFULL
Real-time measurements: voltages, currents, power, cos φ, frequency
Bidirectional active, reactive and apparent energy counters
Average, maximum and minimum values, peaks and max demand
Voltage harmonics and current interharmonics up to the 63rd—
THD and TDD, distortion power factor, K-factor—
Power quality events: dips, undervoltages, overvoltages—
Measurement logging, exportable from the web server—
Oscilloscope via web server and RS485—
MQTT and connection to Chronos Cloud—
Order codes

4 order codes for the EMT132

Choose the type of current sensor and the version, then press + to add the code to the quote request. Click a code to copy it.

InputVersionNo expansion
I · TA 5 A (o 1 A)BASEEMT132.I.BASE
FULLEMT132.I.FULL
V · 333 mV CT or RogowskiBASEEMT132.V.BASE
FULLEMT132.V.FULL

Format: MODEL.INPUT.VERSION · the EMT13x family has no expansions. Configurator and codes for all EMT models →

Accessory: T-BUS connector TBUS-17.5-5P · carries power and RS485, one per meter

Current sensors

Compatible sensors

The sensor depends on the input chosen in the order code. With Chronos CTs the app corrects the signal's magnitude and phase shift.

Sensor code selector →

Downloads

Documentation

  • PDF
    Installation and user manual EMT130 / EMT132
    PDF · IT · 1.7 MB · also in English
  • PDF
    Brochure EMT130 / EMT132
    PDF · IT · 0.3 MB · also in English
  • PDF
    Modbus register map EMT130 / EMT132
    PDF · IT · 1.5 MB · also in English
  • STEP
    3D model EMT132
    STEP · 1 DIN module · 33.3 MB
  • PDF
    CE declaration of conformity EMT132
    coming soon
    Coming soon
  • PDF
    Datasheet: CT and Rogowski current sensors
    PDF · IT · rev. 2 · 0.5 MB
Contact

Talk directly to the people who design.

No call centre: your request goes to an engineer in our technical department.

  • Non-disclosure agreement (NDA) before discussing your project
  • EMT and sensor samples for evaluation on request
Phone +39 049 227 4996 Operating office Via Ceresina 11/E, Selvazzano Dentro (PD), Italy
We process your data according to our privacy notice.