Home › Electrical measurement › Energy meters
Electrical measurement

EMT three-phase energy meters

Five DIN-rail models in two families. Compare them, answer the configurator's questions and find the order code.

EMT power analysers

Find the right EMT in a few questions.

Five three-phase DIN-rail models in two families: the 1-module EMT13x in class 0.5 S, and the 4-module EMT43x in class 0.2 S, with Ethernet, USB and SD.

ModelPower supplyCommunicationIdeal forCommon to the family
EMT130Product page →Self-powered from the measured line85–265 V L-N · 150–450 V L-LRS485 Modbus RTUWi-Fi 2,4 GHzNFCMQTT · FULLDepartment sub-metering and switchboards with little space
  • Class 0.5 Sactive and reactive energy (EN 62053-22 / -24), class C EN 50470
  • 6400 samples/sTRMS measurement, harmonics up to the 63rd order (FULL)
  • TA 5 A o 333 mVbuilt-in integrator for Rogowski coils
  • 160×80 displaycolour, with touch key
  • 1 DIN module93×69×17 mm · IP20 · −25 to +65 °C
  • 1 MB logginginternal flash memory; BASE or FULL versions
EMT132Product page →SELV from the T-BUS connector10–36 Vdc or 19–26 VacRS485 Modbus RTUWi-Fi 2,4 GHzNFCMQTT · FULLRS485 also on T-BUSRows of meters powered from the T-BUS, 24 V switchboards
EMT430Product page →Self-powered from the measured line85–265 V L-N · 150–450 V L-LRS485 Modbus RTUEthernet Modbus TCPWi-Fi 2,4 GHzNFCUSBSDMQTT · FULLExpansion: LoRa or 3 DICloud monitoring without extra wiring
  • Class 0.2 Sactive and reactive energy (EN 62053-22 / -24)
  • 6400 samples/sTRMS measurement, harmonics up to the 63rd order (FULL)
  • TA 5 A o 333 mVbuilt-in integrator for Rogowski coils
  • 2.2" touch displaycolour 320×240, built-in web server
  • 4 DIN modules90×61×72 mm · IP20 · −25 to +65 °C
  • BASE o FULLFULL: power quality, logging, oscilloscope, MQTT, cloud
EMT431Product page →Auxiliary85–265 Vac or 90–350 VdcRS485 Modbus RTUEthernet Modbus TCPWi-Fi 2,4 GHzNFCUSBSDMQTT · FULLExpansion: LoRa or 3 DIMain switchboards and lines that are not always energised
EMT432Product page →Low-voltage auxiliary10–36 Vdc or 19–26 VacRS485 Modbus RTUEthernet Modbus TCPWi-Fi 2,4 GHzNFCUSBSDMQTT · FULLExpansion: LoRa or 1 DIPhotovoltaics, storage, 24 V switchboards

Quick configurator

1 · How much DIN-rail space do you have?
2 · How will you power the meter?
3 · Do you need expansion boards?
4 · BASE or FULL version?
5 · Which current sensors do you use?
Result EMT130 · EMT132 · EMT430 · EMT431 · EMT432

EMT order codes

44 of 44 codes
ModelInputVersionNo exp.LoRaDigital inp.
EMT130IBASEEMT130.I.BASE——
FULLEMT130.I.FULL——
VBASEEMT130.V.BASE——
FULLEMT130.V.FULL——
EMT132IBASEEMT132.I.BASE——
FULLEMT132.I.FULL——
VBASEEMT132.V.BASE——
FULLEMT132.V.FULL——
EMT430IBASEEMT430.I.BASEEMT430.I.BASE.LORAEMT430.I.BASE.DIN
FULLEMT430.I.FULLEMT430.I.FULL.LORAEMT430.I.FULL.DIN
VBASEEMT430.V.BASEEMT430.V.BASE.LORAEMT430.V.BASE.DIN
FULLEMT430.V.FULLEMT430.V.FULL.LORAEMT430.V.FULL.DIN
EMT431IBASEEMT431.I.BASEEMT431.I.BASE.LORAEMT431.I.BASE.DIN
FULLEMT431.I.FULLEMT431.I.FULL.LORAEMT431.I.FULL.DIN
VBASEEMT431.V.BASEEMT431.V.BASE.LORAEMT431.V.BASE.DIN
FULLEMT431.V.FULLEMT431.V.FULL.LORAEMT431.V.FULL.DIN
EMT432IBASEEMT432.I.BASEEMT432.I.BASE.LORAEMT432.I.BASE.DIN
FULLEMT432.I.FULLEMT432.I.FULL.LORAEMT432.I.FULL.DIN
VBASEEMT432.V.BASEEMT432.V.BASE.LORAEMT432.V.BASE.DIN
FULLEMT432.V.FULLEMT432.V.FULL.LORAEMT432.V.FULL.DIN

Format: MODEL.INPUT.VERSION[.EXPANSION] · I = TA 5 A (o 1 A) · V = 333 mV CT or Rogowski · DIN = digital inputs, 3 on EMT430/431, 1 on EMT432

The EMT13x family is available with I o Vinput, without expansions.

Contact

Talk directly to the people who design.

No call centre: your request goes to an engineer in our technical department.

  • Non-disclosure agreement (NDA) before discussing your project
  • EMT and sensor samples for evaluation on request
Phone +39 049 227 4996 Operating office Via Ceresina 11/E, Selvazzano Dentro (PD), Italy
We process your data according to our privacy notice.